PRODUCT OVERVIEW
| Gain (V/A) | Bandwidth | Rise Time | Mode |
|---|---|---|---|
| 1e+4 | 400 Hz | 0 | standard |
| 1e+5 | 400 Hz | 0 | standard |
| 1e+6 | 400 Hz | 0 | standard |
| 1e+7 | 400 Hz | 0 | standard |
| 1e+8 | 150 Hz | 0 | standard |
| 1e+9 | 150 Hz | 0 | standard |
| 1e+10 | 20 Hz | 0 | standard |
| 1e+11 | 20 Hz | 0 | standard |
| 1e+12 | 1 Hz | 0 | standard |
| 1e+13 | 1 Hz | 0 | standard |
| Bandwidth | , 0.7 Hz and 0.1 Hz) |
| Gain | Transimpedance 1 x 104 ... 1 x 1013 V/A (load ≥ 100 kΩ) |
| Input Noise | current gain setting dependent, see table below |
| Output Voltage | ±10 V (load ≥ 100 kΩ) |
OFFICIAL DOCUMENTS
Official technical documents provided by femto.
AI PRODUCT ASSISTANT
Ask technical questions about this femto product. An official datasheet is connected.
TECHNICAL SPECIFICATIONS
| Gain (V/A) | Bandwidth | Rise Time | Mode |
|---|---|---|---|
| 1e+4 | 400 Hz | 0 | standard |
| 1e+5 | 400 Hz | 0 | standard |
| 1e+6 | 400 Hz | 0 | standard |
| 1e+7 | 400 Hz | 0 | standard |
| 1e+8 | 150 Hz | 0 | standard |
| 1e+9 | 150 Hz | 0 | standard |
| 1e+10 | 20 Hz | 0 | standard |
| 1e+11 | 20 Hz | 0 | standard |
| 1e+12 | 1 Hz | 0 | standard |
| 1e+13 | 1 Hz | 0 | standard |
APPLICATIONS
Common measurement applications where this product can be effectively used.
Recommended application for DDPCA-300.
View Application →Recommended application for DDPCA-300.
View Application →Key reasons why this product is recommended for demanding measurement applications.
Optimized for ultra-low current measurements down to the femtoampere range.
Exceptional input noise performance for demanding laboratory measurements.
Ideal when the signal is too small for conventional current amplifiers.
Designed for precision scientific instrumentation and optical experiments.
Stable performance during long-duration precision measurements.
Suitable for photodiodes, APDs and other ultra-sensitive optical detectors.
PRACTICAL ENGINEERING GUIDANCE
Practical setup guidance, measurement cautions and application notes for this product.
Check whether the output is specified for a 50 Ω load or a high-impedance load.
Source: engineering-model
Use the specified high-impedance load when evaluating output-voltage performance.
Source: engineering-model
Include detector and cable capacitance when evaluating stability and bandwidth.
Source: engineering-model
Use proper grounding and cable shielding for low-noise current measurements.
Source: engineering-model
TECHNICAL RESOURCES
LABTECH KOREA
Contact our engineering team for quotations, application support, product comparison and technical consultation.
Request a Quote →